Spectrophotometer Spectroquant® Prove 100

SKU 1.73016.0001

Spectroquant® Prove 100 is a smart spectrophotometer for routine analysis.

The design of Spectroquant® Prove includes a unique port for the cuvette, which allows them to be directly placed without additional action during the study to save time and maximize the efficiency of daily wastewater testing.

The range of wastewater analysis kits includes: CPC, BOD, total organic carbon, phosphorus, ammonium, total nitrogen, nitrates, chromates, lead, volatile organic acids and many more. Test kits can be stored at room temperature. There is no need to wait until the reagent is at room temperature, and there are no fluctuations in results due to temperature variability.

Automated analysis with Live ID

Each Spectroquant® reagent test kit contains an auto selector with a Live ID code. This new identification system not only transmits more data than other barcodes, but also “live” data – thanks to an automatic, free calibration update.

Simply insert the reagent cuvette and auto selector into the Prove 100 spectrophotometer and the instrument will detect the test method, batch number, expiration date, and Live ID calibration update date and calculate the results accordingly. This ensures speed, reliability, simplicity and ease of analysis, reduces the likelihood of operator error, which helps to obtain safe, fully traceable results and simplifies preparation for testing laboratory operation. In addition, due to protection from ambient light during measurement, it is not necessary to close the lid.

Simple documentation

The Prove 100 smart screen provides a clear list of all results, which can be easily filtered by date, time, spectra, method, sample ID, keyword or user. Once you have the results, you can export the data in your preferred form – from a brief overview to a complete protocol. Prove 100 offers several ways to transfer data securely: use USB ports to connect a spectrophotometer to a printer or to save the selected data to a flash drive.

Manufacturer

MERCK

Type of equipment

Spectrophotometers

Type of equipment

Stationary

Measuring range

Vis (320-1100 nm)

Lamp type

Tungsten halogen

The shape of the cuvettes

Rectangular, Round

The size of the cuvettes

10 mm, 16 mm, 20 mm, 50 mm

Additional information

Measurement method: Spectrophotometer with reference beam technology
Operating wavelength range: 320 – 1100 Nm
Lamp type: Tungsten halogen lamp
Measuring modes: Concentration, absorption, transmission, multi-length spectrum scanning, and absorption/transmission kinetacles.
Bandwidth: 4 nm
Wavelength resolution: 1 nm (0.1 nm scan)
Reproducibility of wavelength: ± 0.2 nm
Wavelength accuracy: ± 1 nm
Light scattering: ≤ 0.1% transmission at 340 nm
Photometric measurement range: ± 3.3 Abs
Absorption resolution: 0.001 Abs
Reproduction Absorption: ± 0.003 absorption at 1 absorption from 320 nm to 900 nm
Absorption accuracy: at 340 – 900 nm

1 Abs: ± 0,005 Abs

2 Abs: ± 0,005 Abs

2,5 Abs: ± 0,010 Abs

Scan: Restrictions are freely selected in the wavelength range

Gain: 0,1/1/5 nm

Recording time for full wavelength < : 7 min

Smart Screen: Glass touch screen
Live ID Barcode: Automatic 2-D Barcode Reader System for All Spectroquant® Kits

The barcode contains data about the batch, expiration date and calibration. Data stored during each measurement.

Dimensions of the cuvette: 16 mm round cuvettes and 10, 20, 50 mm rectangular cuvettes
Cuvette holder: The cuvette holder can be removed for easy washing.
Methods: Programmed methods of all Spectroquant® sets, additional user-defined methods: 99 in concentration mode, 20 kinetic modes, 20 scanning modes over the entire wavelength range
Additional methods: Free methods already included in the device database: selenium, mercury, brewery bags (MEBAK/EBC methods), sugar (ICUMSA), oil (DOBI, olive oil)
Environmental light protection: Measurement is possible with the lid open (manufacturer’s patent)
AQA prime: Individual settings for all methods in:

AQA mode 1: Test the device using PhotoCheck and/or Certipur® standards

AQA 2 mode: System inspection with standard CombiCheck or CRM solutions

Special measurement: Direct user access to absorption measurements, transmission measurements, spectra recording and kinetics research.

 

Software updates and methods: Free update from the manufacturer’s website via the Internet, or using a USB drive with an update
Communication: USB: 2 x USB-A (for printer, USB memory device, keyboard, or barcode reader), 1 x USB-B

Ethernet: LAN connection

Storage: 2000 single measured values with concentration, absorption/transmission measurement modes. 20 record results for spectra measurements and 20 result records for kinetic methods.
Language: 28 interface languages
Protection class: IP31 for optics and electronics
Power Supply: Power supply unit with cable 1.2 m. The total length of the cable is 3 m (1.8 m cable to the device and 1.2 m cable to the power supply).
Network requirements: 100 – 230 V, 50-60 Hz
Power consumption: Normal mode: 10W, power storage mode 8.4W.
Temperature: Working: 10 – 35°С. Transportation: -20 – 60 °С up to 24 hours.
Humidity: Working 20 – 80%. Transportation 20 – 95% in the absence of condensate.
Dimensions: 416 x 276 x 237 mm
Mass: about 6.8 kg
Guarantee: Full warranty from the manufacturer for 12 months
EMC: Directives 2004/108/EC, EN IEC61326-1, IEC61326-1
Tool safety: EN 61010-1, UL IEC61010-1

Materials for download

Spectroquant Prove 100.pdf

Spectroquant® Prove 100 is a smart spectrophotometer for routine analysis.

The design of Spectroquant® Prove includes a unique port for the cuvette, which allows them to be directly placed without additional action during the study to save time and maximize the efficiency of daily wastewater testing.

The range of wastewater analysis kits includes: CPC, BOD, total organic carbon, phosphorus, ammonium, total nitrogen, nitrates, chromates, lead, volatile organic acids and many more. Test kits can be stored at room temperature. There is no need to wait until the reagent is at room temperature, and there are no fluctuations in results due to temperature variability.

Automated analysis with Live ID

Each Spectroquant® reagent test kit contains an auto selector with a Live ID code. This new identification system not only transmits more data than other barcodes, but also “live” data – thanks to an automatic, free calibration update.

Simply insert the reagent cuvette and auto selector into the Prove 100 spectrophotometer and the instrument will detect the test method, batch number, expiration date, and Live ID calibration update date and calculate the results accordingly. This ensures speed, reliability, simplicity and ease of analysis, reduces the likelihood of operator error, which helps to obtain safe, fully traceable results and simplifies preparation for testing laboratory operation. In addition, due to protection from ambient light during measurement, it is not necessary to close the lid.

Simple documentation

The Prove 100 smart screen provides a clear list of all results, which can be easily filtered by date, time, spectra, method, sample ID, keyword or user. Once you have the results, you can export the data in your preferred form – from a brief overview to a complete protocol. Prove 100 offers several ways to transfer data securely: use USB ports to connect a spectrophotometer to a printer or to save the selected data to a flash drive.

Manufacturer

MERCK

Type of equipment

Spectrophotometers

Type of equipment

Stationary

Measuring range

Vis (320-1100 nm)

Lamp type

Tungsten halogen

The shape of the cuvettes

Rectangular, Round

The size of the cuvettes

10 mm, 16 mm, 20 mm, 50 mm

Additional information

Measurement method: Spectrophotometer with reference beam technology
Operating wavelength range: 320 – 1100 Nm
Lamp type: Tungsten halogen lamp
Measuring modes: Concentration, absorption, transmission, multi-length spectrum scanning, and absorption/transmission kinetacles.
Bandwidth: 4 nm
Wavelength resolution: 1 nm (0.1 nm scan)
Reproducibility of wavelength: ± 0.2 nm
Wavelength accuracy: ± 1 nm
Light scattering: ≤ 0.1% transmission at 340 nm
Photometric measurement range: ± 3.3 Abs
Absorption resolution: 0.001 Abs
Reproduction Absorption: ± 0.003 absorption at 1 absorption from 320 nm to 900 nm
Absorption accuracy: at 340 – 900 nm

1 Abs: ± 0,005 Abs

2 Abs: ± 0,005 Abs

2,5 Abs: ± 0,010 Abs

Scan: Restrictions are freely selected in the wavelength range

Gain: 0,1/1/5 nm

Recording time for full wavelength < : 7 min

Smart Screen: Glass touch screen
Live ID Barcode: Automatic 2-D Barcode Reader System for All Spectroquant® Kits

The barcode contains data about the batch, expiration date and calibration. Data stored during each measurement.

Dimensions of the cuvette: 16 mm round cuvettes and 10, 20, 50 mm rectangular cuvettes
Cuvette holder: The cuvette holder can be removed for easy washing.
Methods: Programmed methods of all Spectroquant® sets, additional user-defined methods: 99 in concentration mode, 20 kinetic modes, 20 scanning modes over the entire wavelength range
Additional methods: Free methods already included in the device database: selenium, mercury, brewery bags (MEBAK/EBC methods), sugar (ICUMSA), oil (DOBI, olive oil)
Environmental light protection: Measurement is possible with the lid open (manufacturer’s patent)
AQA prime: Individual settings for all methods in:

AQA mode 1: Test the device using PhotoCheck and/or Certipur® standards

AQA 2 mode: System inspection with standard CombiCheck or CRM solutions

Special measurement: Direct user access to absorption measurements, transmission measurements, spectra recording and kinetics research.

 

Software updates and methods: Free update from the manufacturer’s website via the Internet, or using a USB drive with an update
Communication: USB: 2 x USB-A (for printer, USB memory device, keyboard, or barcode reader), 1 x USB-B

Ethernet: LAN connection

Storage: 2000 single measured values with concentration, absorption/transmission measurement modes. 20 record results for spectra measurements and 20 result records for kinetic methods.
Language: 28 interface languages
Protection class: IP31 for optics and electronics
Power Supply: Power supply unit with cable 1.2 m. The total length of the cable is 3 m (1.8 m cable to the device and 1.2 m cable to the power supply).
Network requirements: 100 – 230 V, 50-60 Hz
Power consumption: Normal mode: 10W, power storage mode 8.4W.
Temperature: Working: 10 – 35°С. Transportation: -20 – 60 °С up to 24 hours.
Humidity: Working 20 – 80%. Transportation 20 – 95% in the absence of condensate.
Dimensions: 416 x 276 x 237 mm
Mass: about 6.8 kg
Guarantee: Full warranty from the manufacturer for 12 months
EMC: Directives 2004/108/EC, EN IEC61326-1, IEC61326-1
Tool safety: EN 61010-1, UL IEC61010-1

Materials for download