Preprogrammed for precision
Prove 600 is preprogrammed to measure more than 200 analytes using Spectroquant® kits and techniques, including the most sensitive tests for chlorides, silicates, phosphates, iron, and sulfates. Test kits can be stored at room temperature. There is no need to wait until the reagent is at room temperature, and there are no fluctuations in results due to temperature variability.
Larger cuvette size, highest sensitivity
In addition to 10, 20 and 50 mm cuvettes, Prove 600 is also compatible with 100 mm formats for even greater sensitivity. Modern methods using a 100 mm cuvette include: silicate in process water, iron in drinking water and phosphate in surface or process water.
Live ID for maximum security
Each Spectroquant® reagent test kit contains an auto selector with a Live ID code. This new identification system not only transmits more data than other barcodes, but also “live” data – thanks to an automatic, free calibration update.
Simply insert the reagent cuvette and auto selector into the Prove 600 spectrophotometer and the instrument will detect the test method, batch number, expiration date, and Live ID calibration update date and calculate the results accordingly. This ensures speed, reliability, simplicity and ease of analysis, reduces the likelihood of operator error, which helps to obtain safe, fully traceable results and simplifies preparation for testing laboratory operation. In addition, due to protection from ambient light, it is not necessary to close the lid during measurement.
Simple documentation
The Prove 600 smart screen provides a clear list of all results, which can be easily filtered by date, time, spectra, method, sample ID, keyword or user. Once you have the results, you can export the data in your preferred form – from a brief overview to a complete protocol. Prove 600 offers several ways to transfer data securely: use
Manufacturer | MERCK |
---|---|
Type of equipment | Spectrophotometers |
Type of equipment | Stationary |
Measuring range | UV (190-320 nm), Vis (320-1100 nm) |
Lamp type | Xenon |
The shape of the cuvettes | Rectangular, Round |
The size of the cuvettes | 10 mm, 100 mm, 16 mm, 20 mm, 50 mm |
Additional information
Measurement method | Spectrophotometer with reference beam technology |
Operating wavelength range | 190 – 1100 nm |
Lamp type | Xenon pulse lamp |
Measurement modes | Concentration, absorption, transmission, multi-length spectrum scanning and absorption/transmission kinetics. |
Bandwidth | 1.8 nm |
Toluene/hexane ratio | > Fig. 1.4 – the ratio of spectrum throughput to resolution for a standard toluene solution in hexane, measured at an ambient temperature of 25°C |
Wavelength resolution | 1 nm (0.1 nm scan) |
Wavelength reproducibility | ± 0.1 nm |
Wavelength accuracy | ± 1 nm |
Light scattering | ≤ 0.1% transmission at 340 nm; ≤ 1% transmittance at 198 nm |
Photometric measurement range | ± 3.3 Abs |
Absorption resolution | 0.001 Abs |
Reproduction absorption | ± 0.003 absorption at 1 absorption from 200 nm to 900 nm |
Absorption accuracy | at 230 – 900 nm
1 Abs: ± 0,004 Abs 2 Abs: ± 0,004 Abs 2,5 Abs: ± 0,006 Abs |
Scan | Restrictions are freely selected in the wavelength range
Gain: 0,1/1/5 nm Recording time for full wavelength < : 7 min |
Smart Screen | Glass touch screen |
Live ID Barcode | Automatic 2-D Barcode Reader System for All Spectroquant® Kits
The barcode contains data about the batch, expiration date and calibration. Data stored during each measurement. |
Dimensions of the cuvette | 16 mm round cuvettes and 10, 20, 50, 100 mm rectangular cuvettes |
Cuvette holder | The cuvette holder can be removed for easy washing. |
Methods. | Programmed methods of all Spectroquant® sets, additional user-defined methods: 99 in concentration mode, 20 kinetic modes, 20 scanning modes over the entire wavelength range |
Additional methods | Free methods already included in the device database: selenium, mercury, brewery bags (MEBAK/EBC methods), sugar (ICUMSA), oil (DOBI, olive oil) |
Protection from environmental light | Measurement is possible with the lid open (manufacturer’s patent) |
AQA prime | Individual settings for all methods in:
AQA mode 1: Test the device using PhotoCheck and/or Certipur® standards AQA 2 mode: System inspection with standard CombiCheck or CRM solutions |
Special measurement | Direct user access to absorption measurements, transmission measurements, spectra recording and kinetics research.
|
Software updates and methods | Free update from the manufacturer’s website via the Internet, or using a USB drive with an update |
Communication | USB: 2 x USB-A (for printer, USB memory device, keyboard, or barcode reader), 1 x USB-B
Ethernet: LAN connection |
Storage | 2000 single measured values with concentration, absorption/transmission measurement modes. 20 record results for spectra measurements and 20 result records for kinetic methods. |
Languages | 28 interface languages |
Protection class | IP31 for optics and electronics |
Power supply | Power supply unit with cable 1.2 m. The total length of the cable is 3 m (1.8 m cable to the device and 1.2 m cable to the power supply). |
Network requirements | 100 – 230 V, 50-60 Hz |
Power consumption | Normal mode: 10W, power storage mode 8.4W. |
Temperature | Working: 10 – 35°С. Transportation: -20 – 60 °С up to 24 hours. |
Humidity | Working 20 – 80%. Transportation 20 – 95% in the absence of condensate. |
Dimensions | 416 x 276 x 237 mm |
Mass | about 6.8 kg |
Guarantee | Full warranty from the manufacturer for 12 months |
EMC | Directives 2004/108/EC, EN IEC61326-1, IEC61326-1 |
Tool Security | EN 61010-1, UL IEC61010-1 |
Materials for download
Preprogrammed for precision
Prove 600 is preprogrammed to measure more than 200 analytes using Spectroquant® kits and techniques, including the most sensitive tests for chlorides, silicates, phosphates, iron, and sulfates. Test kits can be stored at room temperature. There is no need to wait until the reagent is at room temperature, and there are no fluctuations in results due to temperature variability.
Larger cuvette size, highest sensitivity
In addition to 10, 20 and 50 mm cuvettes, Prove 600 is also compatible with 100 mm formats for even greater sensitivity. Modern methods using a 100 mm cuvette include: silicate in process water, iron in drinking water and phosphate in surface or process water.
Live ID for maximum security
Each Spectroquant® reagent test kit contains an auto selector with a Live ID code. This new identification system not only transmits more data than other barcodes, but also “live” data – thanks to an automatic, free calibration update.
Simply insert the reagent cuvette and auto selector into the Prove 600 spectrophotometer and the instrument will detect the test method, batch number, expiration date, and Live ID calibration update date and calculate the results accordingly. This ensures speed, reliability, simplicity and ease of analysis, reduces the likelihood of operator error, which helps to obtain safe, fully traceable results and simplifies preparation for testing laboratory operation. In addition, due to protection from ambient light, it is not necessary to close the lid during measurement.
Simple documentation
The Prove 600 smart screen provides a clear list of all results, which can be easily filtered by date, time, spectra, method, sample ID, keyword or user. Once you have the results, you can export the data in your preferred form – from a brief overview to a complete protocol. Prove 600 offers several ways to transfer data securely: use
Manufacturer | MERCK |
---|---|
Type of equipment | Spectrophotometers |
Type of equipment | Stationary |
Measuring range | UV (190-320 nm), Vis (320-1100 nm) |
Lamp type | Xenon |
The shape of the cuvettes | Rectangular, Round |
The size of the cuvettes | 10 mm, 100 mm, 16 mm, 20 mm, 50 mm |
Additional information
Measurement method | Spectrophotometer with reference beam technology |
Operating wavelength range | 190 – 1100 nm |
Lamp type | Xenon pulse lamp |
Measurement modes | Concentration, absorption, transmission, multi-length spectrum scanning and absorption/transmission kinetics. |
Bandwidth | 1.8 nm |
Toluene/hexane ratio | > Fig. 1.4 – the ratio of spectrum throughput to resolution for a standard toluene solution in hexane, measured at an ambient temperature of 25°C |
Wavelength resolution | 1 nm (0.1 nm scan) |
Wavelength reproducibility | ± 0.1 nm |
Wavelength accuracy | ± 1 nm |
Light scattering | ≤ 0.1% transmission at 340 nm; ≤ 1% transmittance at 198 nm |
Photometric measurement range | ± 3.3 Abs |
Absorption resolution | 0.001 Abs |
Reproduction absorption | ± 0.003 absorption at 1 absorption from 200 nm to 900 nm |
Absorption accuracy | at 230 – 900 nm
1 Abs: ± 0,004 Abs 2 Abs: ± 0,004 Abs 2,5 Abs: ± 0,006 Abs |
Scan | Restrictions are freely selected in the wavelength range
Gain: 0,1/1/5 nm Recording time for full wavelength < : 7 min |
Smart Screen | Glass touch screen |
Live ID Barcode | Automatic 2-D Barcode Reader System for All Spectroquant® Kits
The barcode contains data about the batch, expiration date and calibration. Data stored during each measurement. |
Dimensions of the cuvette | 16 mm round cuvettes and 10, 20, 50, 100 mm rectangular cuvettes |
Cuvette holder | The cuvette holder can be removed for easy washing. |
Methods. | Programmed methods of all Spectroquant® sets, additional user-defined methods: 99 in concentration mode, 20 kinetic modes, 20 scanning modes over the entire wavelength range |
Additional methods | Free methods already included in the device database: selenium, mercury, brewery bags (MEBAK/EBC methods), sugar (ICUMSA), oil (DOBI, olive oil) |
Protection from environmental light | Measurement is possible with the lid open (manufacturer’s patent) |
AQA prime | Individual settings for all methods in:
AQA mode 1: Test the device using PhotoCheck and/or Certipur® standards AQA 2 mode: System inspection with standard CombiCheck or CRM solutions |
Special measurement | Direct user access to absorption measurements, transmission measurements, spectra recording and kinetics research.
|
Software updates and methods | Free update from the manufacturer’s website via the Internet, or using a USB drive with an update |
Communication | USB: 2 x USB-A (for printer, USB memory device, keyboard, or barcode reader), 1 x USB-B
Ethernet: LAN connection |
Storage | 2000 single measured values with concentration, absorption/transmission measurement modes. 20 record results for spectra measurements and 20 result records for kinetic methods. |
Languages | 28 interface languages |
Protection class | IP31 for optics and electronics |
Power supply | Power supply unit with cable 1.2 m. The total length of the cable is 3 m (1.8 m cable to the device and 1.2 m cable to the power supply). |
Network requirements | 100 – 230 V, 50-60 Hz |
Power consumption | Normal mode: 10W, power storage mode 8.4W. |
Temperature | Working: 10 – 35°С. Transportation: -20 – 60 °С up to 24 hours. |
Humidity | Working 20 – 80%. Transportation 20 – 95% in the absence of condensate. |
Dimensions | 416 x 276 x 237 mm |
Mass | about 6.8 kg |
Guarantee | Full warranty from the manufacturer for 12 months |
EMC | Directives 2004/108/EC, EN IEC61326-1, IEC61326-1 |
Tool Security | EN 61010-1, UL IEC61010-1 |